Winland EA200 2 Zone EnviroAlert Monitoring Device

Winland EA200 2 Zone EnviroAlert Monitoring Device

Item#: EA200
Monitor two zones with one on-board temperature sensor and an additional remote temperature, humidity or water sensing probe. If temperatures and/or humidity deviate from the preset limits or water forms a bridge between the contacts on the WaterBug® sensor, the designate relay for each zone will activate an alarm, dialer, siren, etc.
Availability:In Stock. Order by 2pm EST for same-business-day shipping.
Options:
$98.95
 
  • Overview
  • Features
  • Specs
  • Manuals / Downloads
  • Related
  • Reviews
  • Also Bought

Monitor two zones with one on-board temperature sensor and an additional remote temperature, humidity or water sensing probe. If temperatures and/or humidity deviate from the preset limits or water forms a bridge between the contacts on the WaterBug® sensor, the designate relay for each zone will activate an alarm, dialer, siren, etc.

This unit does not come with a power supply. 12vdc Power supply is available for purchase separately (p/n 1111), 24vdc power supply available (p/n FGD-0054)or you may provide your own.



  • Available in 12 and 24 volt models (EA200-12 and EA200-24)
  • Simultaneous operation of both zones
  • Defrost time delay up to 120 minutes
  • Easy to read large LCD display
  • Eight event alarm memory with time and date
  • Auxiliary output relay for local audible alarm
  • Auxiliary alarm silence feature with 10 minute timer
  • Each zone has offset calibration adjustment
  • Temperature and Humidity high/low set points
  • Output relays can be configured to be initially energized or de-energized
  • Tamper proof lock setting
  • Snap fit mounting base with main housing for easy access
  • Plug in terminal strip connectors for easier wire termination
  • Zones being monitored are displayed every few seconds
  • Display F°, C°, % (Humidity) or Water Drop icon
  • Zone configuration retained in memory if power is lost


 

 
 
 
EA200-12
EA200-24
Power Requirements
 
11 to 14 VDC @ 120mA
23 to 26 VDC @ 120mA

 

Remote Sensor Inputs
 

 

1 (Zone 2)

 

On-Board Temp Sensor
 

 

Zone 1 - ambient temp sensor

32° to 122°F (0° to 50°C)
 

 

 

Unit Operating Range
 

 

32° to 122°F (0° to 50°C)
Non-condensing environment. Indoor use only.
 

 

 

Low/High Limit Adjust Range
 

 

-58° to 299°F (-50° to 150°C)

 

Alarm Outputs
 

 

2 Form C Relays (N.O./N.C.) 1A @ 30 VDC
(Configurable)
 

 

 

Auxiliary Alarm Output
 

 

1 Form C Relay (N.O./N.C.)
(Non-Configurable)
 

 

 

Alarm Time Delay
 

 

0 to 120 mintues
(program independently for each zone)
 

 

 

Console Weight
 

 

.55 lb (.25kg)

 

Console Dimensions
 

 

6 x 4.75 x 1.25" (15.24 x 12.07 x 3.18 cm)

 

Case Material
 

 

ABS

 

Mounting
 

 

2-gang box or surface mount