Winland WaterBug 200 Water/Flood Sensor 12VDC (WB-200)

Winland WaterBug 200 Water/Flood Sensor 12VDC (WB-200)

Item#: WB200
The model WB-200 operates on 12 or 24 Volt AC/DC and has a form C relay output that can be connected to alarm panels, bells, dialers, etc. The unit can monitor up to as many as six sensor probes wired in parallel, up to 100 feet away using 22-18 AWG twisted pair. Each sensor probe has two contacts.
$75.99
Availability:In Stock. Order by 2pm EST for same-business-day shipping.
$75.99
 

  • Overview
  • Features
  • Specs
  • Contents
  • Comparison / Tutorials
  • Manuals / Downloads
  • Related

The model WB-200 operates on 12 or 24 Volt AC/DC and has a form C relay output that can be connected to alarm panels, bells, dialers, etc. The unit can monitor up to as many as six sensor probes wired in parallel, up to 100 feet away using 22-18 AWG twisted pair. Each sensor probe has two contacts. When a film of water forms a bridge between these contacts, the unit senses this and triggers the alarm output. The sensor will not alarm due to condensation or high humidity. One standard surface sensor is included with the unit.

Power Supply Sold Separately - See part number XFR-0024


Typical Applications:

  • Residential or Vacation Homes
  • Basement Sump Pumps
  • Commercial Buildings
  • Office and Computer Areas
  • Unattended Buildings
  • Greenhouses & Animal Buildings
  • All Drain Areas
  • Sprinkler Systems

Accessory Options:

  • Versatile 12 or 24 Volt AC/DC power for operation
  • No false alarms due to condensation or humidity
  • Can monitor up to 6 sensor probes - up to 100 feet away
  • Provides (1) form "C" contact closure output for alarm
  • Easy surface mount installation
  • Can be used to detect absence of water
  • Designed to detect nonflammable conductive liquids (distilled water cannot be detected.)
  • One year parts and labor; subject to conditions of limited warranty.
  • Console Size: 4.1" x 2.36" x 1.18" (10 cm x 6 cm x 3 cm)(with flanges)
  • Probe Size (standard P/N #M-001-0106): 2" x 3" x 0.88" (5.1 cm x 7.6 cm x 2.2 cm)
  • Probe Size (under carpet P/N #M-001-0107): 2" x 3" x 0.88" (5.1 cm x 7.6 cm x 0.5 cm)
  • Power Requirements (resting state): 12V or 24V AC or DC
  • Power Requirements (alarm condition): 5mA @ 12V or 24V AC, or 13.5mA @ 12V or 24V DC
  • Sensitivity: Will not alarm due to high humidity or condensation
  • Operating Temperature: Control and Probe 32 to +140 F (0 to +60 C)
  • Outputs: Form C (SPDT) 1 Amp @ 24Vac, 1 Amp @ 30 VDC (not for direct high voltage switching)
  • Recomended Dist. Between Probes & Console: 1-2 probes: 200ft (61 m) max. 3 or more probes: 100ft (30.5 m) per probe
  • Recommended Max. Probes Per Console: 6
No information available at this time. Feel free to contact us for further information